Every New Zealand regulation's sizes for a corridor or a path, side by side. Millimetres unless marked.
- D1/AS1Second Edition Amendment 61 Jan 2017
- NZS 4121:2001
- C/AS1Second Edition Amendment 128 Jul 2025
- C/AS2Second Edition28 Jul 2025
- Kāinga Ora v2.1
- Lifemark v2
| Building Code and standards | Client and rating | ||||||
|---|---|---|---|---|---|---|---|
| D1/AS1 | NZS 4121 | C/AS1 | C/AS2 | Kāinga Ora | Lifemark | ||
| Width | |||||||
| A | Clear width | ≥1200 | ≥1200 | ≥700 | ≥850 | ≥1050 | ≥1050 |
| exitway | ≥1000 | ||||||
| hospital exitway | ≥1200 | ||||||
| single escape route | ≥700 | ||||||
| upper floor | ≥1000 | ||||||
| with a turning circle | ≥1200 | ||||||
| B | Path outside | ≥1200 | ≥1200 | ≥1000 | ≥1000 | ≥1200 | |
| to an apartment building | ≥1200 | ||||||
| secondary, from parking | ≥800 | ||||||
| to the clothesline | ≥600 | ||||||
| Escape width, per person | ≥7 | ||||||
| hospital | ≥8 | ||||||
| Height and projections | |||||||
| C | Headroom | ≥2100 | ≥2100 | ||||
| shorter than 2000 long | ≥2000 | ≥2000 | |||||
| under signs and lights | ≥2000 | ||||||
| D | Handrail, into the width | ≤100 | ≤100 | ≤100 | |||
| other, below 800 high | <100 | ||||||
| 800 to 1600 high | <60 | ||||||
| above 1600 high | <200 | ||||||
| Levels and edges | |||||||
| E | Cross fall | ≤1:50 | ≤1:50 | ≤1:50 | ≤1:50 | ||
| at least, to drain | ≥1:100 | ≥1:100 | |||||
| F | Slope along, before a ramp | ≤1:20 | |||||
| path to the entrance | ≤1:16 | ||||||
| G | Rest area, length | ≥1200 | |||||
| apart, on 1:33 to 1:20 | ≤18 m | ||||||
| H | Upstand, raised over 25 | ≥75 | |||||