Corridor and path dimensions

Every New Zealand regulation's sizes for a corridor or a path, side by side. Millimetres unless marked.

  • D1/AS1Second Edition Amendment 61 Jan 2017
  • NZS 4121:2001
  • C/AS1Second Edition Amendment 128 Jul 2025
  • C/AS2Second Edition28 Jul 2025
  • Kāinga Ora v2.1
  • Lifemark v2
ADPlanCSectionBEHPath, acrossFGPath, along
Building Code and standardsClient and rating
D1/AS1NZS 4121C/AS1C/AS2Kāinga OraLifemark
Width
AClear width≥1200≥1200≥700≥850≥1050≥1050
exitway≥1000
hospital exitway≥1200
single escape route≥700
upper floor≥1000
with a turning circle≥1200
BPath outside≥1200≥1200≥1000≥1000≥1200
to an apartment building≥1200
secondary, from parking≥800
to the clothesline≥600
Escape width, per person≥7
hospital≥8
Height and projections
CHeadroom≥2100≥2100
shorter than 2000 long≥2000≥2000
under signs and lights≥2000
DHandrail, into the width≤100≤100≤100
other, below 800 high<100
800 to 1600 high<60
above 1600 high<200
Levels and edges
ECross fall≤1:50≤1:50≤1:50≤1:50
at least, to drain≥1:100≥1:100
FSlope along, before a ramp≤1:20
path to the entrance≤1:16
GRest area, length≥1200
apart, on 1:33 to 1:20≤18 m
HUpstand, raised over 25≥75

Each figure is its document's, its paragraph on hover, and holds where its column and row say. Kāinga Ora's are for the homes it builds and Lifemark's for a home seeking its rating: neither is the Building Code. This compares documents; it is not the whole of any of them.

building.govt.nz